Updated

Milvue in numbers

Milvue is a French artificial intelligence company for radiology, based in Paris and Montreal. Its software equips more than 600 sites in 25 countries and runs 40 million analyses a year. The Milvue Suite (TechCare Alert for detection, TechCare Metrics for measurements) is a Class IIa medical device in Europe, cleared by the FDA and licensed by Health Canada; TechCare Report, the dictation and reporting app, is not a medical device.

Footprint

FigureWhat it measuresSourceDate
600+ sitesImaging sites equipped with the Milvue Suite, cloud and on-premiseMilvue installed base countJune 2026
25 countriesCountries where Milvue is presentMilvueJune 2026
40 million analyses a yearImage analyses run by Milvue software over one yearMilvue activity data2026
2 officesHeadquarters in Paris (35 rue Vaugelas, 75015) and Milvue North America in Montreal (Suite 500, 355 rue Sainte-Catherine Ouest, H3B 1A5)MilvueOctober 2026

Clearances

TerritoryProductClearanceDate
European UnionMilvue Suite (TechCare Alert, TechCare Metrics)Class IIa medical device, EU MDR 2017/745, notified body BSI, CE 2797. ISO 13485 certified quality system (certificate MD 709839). Fracture detection with no age limit.In force
United StatesTechCare Trauma (fracture detection)FDA 510(k) K242171, Class II deviceJanuary 17, 2025
United StatesSmartChest (chest X-ray, adults)FDA 510(k) K232410, Class II deviceMay 10, 2024
CanadaSmartTrauma, TechCare MetricsHealth Canada, Class II devices, patients aged 1 and aboveSmartTrauma: February 23, 2023; TechCare Metrics: October 10, 2025
United KingdomFracture detectionNICE HTG739: one of four technologies that can be used in the NHS while more evidence is generatedJanuary 2025

Published clinical evidence

StudyPopulationResult for Milvue
Bousson et al., Academic Radiology, 2023, doi:10.1016/j.acra.2023.06.0161,210 emergency patients, three commercial algorithms compared90.1% fracture-detection accuracy, versus 88.8% and 71.0% for the other two tools: the highest fracture-detection accuracy in published independent head-to-head studies
Altmann-Schneider et al., Pediatric Radiology, 2025, doi:10.1007/s00247-025-06461-63,013 children aged 2 to 17, University Children's Hospital ZurichFracture-detection sensitivity and specificity: lower leg 90.0% and 98.8%, forearm 94.7% and 96.4%, elbow 91.6% and 82.4%
van Leeuwen et al., Radiology, 2024, doi:10.1148/radiol.230981386 chest radiographs, 17 radiologist readers, 7 software productsLung nodule: AUC 0.86, statistically above the mean of the 17 radiologists (0.81, p = 0.04)
European Journal of Radiology Open, 2023, doi:10.1016/j.ejro.2023.1004821,772 emergency patients, bone and chestAUC 0.954; the AI catches about 90% of misread radiographs
Zerouali et al., Diagnostic and Interventional Imaging, 2023, doi:10.1016/j.diii.2023.03.003100 patients, median age 14Cobb angle: mean absolute error 2.90°, ICC 0.95
Tanzilli et al., AI (MDPI), 2025, doi:10.3390/ai6070144105 adults, weight-bearing foot radiographsHallux valgus: 94% accuracy (sensitivity 91.1%, specificity 97.2%); flat or high-arched foot: 98% accuracy
Reader study of the TechCare Trauma FDA submissionReaders with and without the AI+22% reader sensitivity for fracture detection in adults, +20% in children; standalone AI AUC 0.962

TechCare Report

FigureWhat it measuresSourceDate
1 million+ reportsReports produced with TechCare Report, integrated in the Milvue Suite and as a web appMilvue activity data2026
20 languagesDictation and report languages (French, English, German, Spanish, Italian, Dutch, Portuguese, Polish, Romanian, Czech, Danish, Swedish, Norwegian, Hungarian, Russian, Arabic, Mandarin, Hindi, Korean and Armenian)TechCare Report appOctober 2026
Up to 4× fewer errorsSpeech recognition errors, compared with leading general-purpose modelsMilvue benchmark, 191 radiology dictationsOctober 2026
14 daysFull access on sign-up, no credit cardTechCare Report appOctober 2026
4 plansStarter free (up to 40 reports a month); Essential €19.99 a month or €199.90 a year; Pro €59.99 a month or €599.90 a year; Enterprise on quoteTechCare Report appOctober 2026

The Milvue Suite software, developed by Milvue, is a Class IIa medical device under EU Regulation MDR 2017/745 - Notified body: BSI, CE 2797. TechCare Report, report-drafting assistance software, is not a medical device.

Cite this page: Milvue, "Milvue in numbers", updated October 2, 2026, https://www.milvue.com/en/milvue-in-numbers/